SIMATIC WINAC SLOT 412 V3.2, SINGLE LICENSE F. 1 INSTALL., INCL R-SW, SW AND DOCU. ON CD, CLASS A, 3 LANGUAGES (G,E,F), EXECUTABLE UNDER WIN NT/2000, REFERENCE-HW: SIMATIC PC |
General information |
Hardware product version |
1 |
Firmware version |
V3.0 |
Input current |
Current consumption, max. |
1.5 A; from PCI bus without PS Extension Board; 0.3 A with PS Extension Board; current consumption 12 V/24 V via PS Extension Board 1.2 A |
Power |
Power consumption, typ. |
12 W |
Memory |
Work memory |
● Integrated |
256 kbyte; 128 Kbytes code 128 Kbytes data |
Load memory |
● expandable FEPROM |
Yes; Memory Card (FLASH) up to 64 MB |
● expandable FEPROM, max. |
64 Mbyte |
● integrated RAM, max. |
256 kbyte |
● expandable RAM |
Yes; Memory Card (FLASH) up to 64 MB |
● expandable RAM, max. |
16 Mbyte |
Battery |
Backup battery |
● Backup current, typ. |
130 µA |
● Backup current, max. |
500 µA; Backup battery voltage: 3.6 V Lithium |
CPU processing times |
for bit operations, typ. |
0.2 µs |
for fixed point arithmetic, typ. |
0.2 µs |
for floating point arithmetic, typ. |
0.6 µs |
CPU-blocks |
DB |
● Number, max. |
512 |
● Size, max. |
64 kbyte |
FB |
● Number, max. |
256 |
● Size, max. |
64 kbyte |
FC |
● Number, max. |
256 |
● Size, max. |
64 kbyte |
OB |
● Size, max. |
64 kbyte |
● Number of time alarm OBs |
2 |
● Number of delay alarm OBs |
2 |
● Number of time interrupt OBs |
2 |
● Number of process alarm OBs |
2 |
Nesting depth |
● per priority class |
24 |
● additional within an error OB |
2 |
Counters, timers and their retentivity |
S7 counter |
● Number |
256 |
Retentivity |
— can be set |
Yes |
— lower limit |
0 |
— upper limit |
255 |
— preset |
Z 0 to Z 7 |
Counting range |
— can be set |
Yes |
— lower limit |
1 |
— upper limit |
999 |
IEC counter |
● present |
Yes |
● Type |
SFB |
S7 times |
● Number |
256 |
Retentivity |
— lower limit |
0 |
— upper limit |
255 |
— preset |
No retentivity |
Time range |
— lower limit |
10 ms |
— upper limit |
9 990 s |
IEC timer |
● present |
Yes |
● Type |
SFB |
Data areas and their retentivity |
Retentivity without UPS and PS Extension Board |
none |
Retentivity with UPS |
none |
Retentivity with PS extension board and battery |
all data |
Flag |
● Number, max. |
4 kbyte |
● of which retentive |
From MB 0 to MB 4095 |
● Retentivity preset |
MB 0 to MB 15 |
● Number of clock memories |
8 |
Address area |
I/O address area |
● Inputs |
4 kbyte |
● Outputs |
4 kbyte |
of which, distributed |
— MPI/DP interface, inputs |
2 kbyte |
— MPI/DP interface, outputs |
2 kbyte |
— DP interface, inputs |
4 kbyte |
— DP interface, outputs |
2 kbyte |
Process image |
● Inputs, adjustable |
4 kbyte |
● Outputs, adjustable |
4 kbyte |
● Inputs, default |
128 byte |
● Outputs, default |
128 byte |
Subprocess images |
● Number of subprocess images, max. |
8 |
Digital channels |
● Inputs |
32 768 |
● Outputs |
32 768 |
Analog channels |
● Inputs |
2 048 |
● Outputs |
2 048 |
Hardware configuration |
Number of single-width slots, max. |
1; 2 with PC extension board; PCI format 3/4 |
Number of DP masters |
● overall |
2 |
● Integrated |
2 |
Number of operable FMs and CPs (recommended) |
● FM |
FM 350-1 / 350-2, FM 351, FM 352, FM 353, FM 355 / 355-2 |
● CP, LAN |
Over PC CP |
Time of day |
Clock |
● Hardware clock (real-time clock) |
Yes |
● battery-backed and synchronizable |
Yes |
Clock synchronization |
● supported |
Yes; to PC-CP: Slave |
● to MPI, master |
Yes |
● to MPI, slave |
Yes |
Interfaces |
1st interface |
Physics |
RS 485 / PROFIBUS |
Isolated |
Yes |
Functionality |
● MPI |
Yes |
● DP master |
Yes |
● DP slave |
Yes |
MPI |
● Number of connections |
16 |
● Transmission rate, max. |
12 Mbit/s |
Services |
— PG/OP communication |
Yes |
— Routing |
Yes |
— Global data communication |
Yes |
— S7 basic communication |
Yes |
— S7 communication |
Yes |
DP master |
● Number of connections, max. |
16 |
● Transmission rate, max. |
12 Mbit/s |
● Number of DP slaves, max. |
32 |
Services |
— PG/OP communication |
Yes |
— Global data communication |
No |
— S7 basic communication |
Yes |
— S7 communication |
Yes |
— Equidistance mode support |
Yes |
— SYNC/FREEZE |
Yes |
— Activation/deactivation of DP slaves |
Yes |
— Direct data exchange (slave-to-slave communication) |
Yes |
— DPV0 |
Yes |
— DPV1 |
Yes |
Address area |
— Inputs, max. |
2 kbyte |
— Outputs, max. |
2 kbyte |
User data per DP slave |
— User data per DP slave, max. |
244 byte; 244 byte / 244 byte |
DP slave |
Services |
— Routing |
Yes |
2nd interface |
Physics |
RS 485 / PROFIBUS |
Isolated |
Yes |
Functionality |
● MPI |
No |
● DP master |
Yes |
● DP slave |
Yes |
DP master |
● Number of connections, max. |
16 |
● Transmission rate, max. |
12 Mbit/s |
● Number of DP slaves, max. |
64 |
Services |
— PG/OP communication |
Yes |
— Routing |
Yes |
— Global data communication |
No |
— S7 basic communication |
Yes |
— S7 communication |
Yes |
— Equidistance mode support |
Yes |
— SYNC/FREEZE |
Yes |
— Activation/deactivation of DP slaves |
Yes |
— Direct data exchange (slave-to-slave communication) |
Yes |
— DPV0 |
Yes |
— DPV1 |
Yes |
Address area |
— Address area, max. |
4 kbyte; 4 KB/4 KB |
User data per DP slave |
— User data per DP slave, max. |
244 byte; 244 byte / 244 byte |
DP slave |
Services |
— PG/OP communication |
Yes |
— Routing |
Yes |
Isochronous mode |
Isochronous operation (application synchronized up to terminal) |
No |
Communication functions |
PG/OP communication |
Yes |
Global data communication |
● supported |
Yes |
S7 basic communication |
● supported |
Yes |
S7 communication |
● as server |
Yes |
● As client |
Yes |
Number of connections |
● overall |
16 |
● usable for PG communication |
|
— reserved for PG communication |
1 |
● usable for OP communication |
|
— reserved for OP communication |
1 |
S7 message functions |
Number of login stations for message functions, max. |
8 |
SCAN procedure |
Yes |
Process diagnostic messages |
Yes; Alarm_S |
Alarm 8-blocks |
Yes |
Process control messages |
Yes |
Test commissioning functions |
Status block |
Yes |
Single step |
Yes |
Status/control |
● Status/control variable |
Yes |
Forcing |
● Forcing |
Yes |
Diagnostic buffer |
● present |
Yes |
● Number of entries, max. |
|
— preset |
120 |
Hardware requirements |
Hardware required |
Accessories: color monitor, keyboard, mouse or pointer for Windows |
Main memory, min. |
128 Mbyte |
Required memory on hard disk, min. |
60 Mbyte |
Processor |
Intel Pentium 300 MHz |
Operating systems |
Configuration |
Software interface |
C/C with WinAC Slot T-Kit |
Configuration software |
● STEP 7 |
Yes; as of V5 |
programming |
● Nesting levels |
8 |
Programming language |
— LAD |
Yes |
— FBD |
Yes |
— STL |
Yes |
— SCL |
Yes |
— CFC |
Yes |
— GRAPH |
Yes |
— HiGraph® |
Yes |
Software libraries |
— Easy Motion Control |
Yes |
Know-how protection |
● User program protection/password protection |
Yes |
Open Development interfaces |
● SMX (Shared Memory Extension) |
|
— Inputs |
4 kbyte |
— Outputs |
4 kbyte |
Dimensions |
Width |
98 mm |
Height |
288 mm |
Weights |
Weight, approx. |
250 g; 450 g with PC extension board |
last modified: |
14.10.2014 |