![](/storage/image/d/image/data/SIEMENS_Original/6ES7/138/6ES7138-4CF03-0AB0/6ES71384CF030AB0.jpg) |
SIMATIC DP, POWER MODULE PM-E F PROFISAFE, FOR ET 200S; 24V DC USEABLE FOR INSTALLATIONS WITH UNGROUNDED REFERENCE POTENTIAL RELAIS FOR FAIL-SAFE SWITCHING OF VOLTAGE BUSES P1 AND P2 UP TO CATEGORY 3 (EN954-1)/ SIL2 (IEC61508)/PLD (ISO13849), 2 FAIL-SAFE DIGITAL OUTPUTS UP TO CATEGORY 4 (EN954-1)/ SIL3 (IEC61508)/PLE (ISO13849), ALSO USEABLE IN PROFINET-NETWORKS W. IM151-3 HF |
Supply voltage |
Load voltage L |
● Rated value (DC) |
24 V |
● Reverse polarity protection |
No |
Input current |
from load voltage L (without load), max. |
typ. 100 mA |
from backplane bus 24 V DC, max. |
28 mA |
Current carrying capacity |
Current carrying capacity up to 40 °C, max. |
10 A |
Current carrying capacity up to 60 °C, max. |
6 A |
Power losses |
Power loss, typ. |
4 W |
Address area |
Address space per module |
● without packing |
5 byte; Input and output in each case |
Digital inputs |
Cable length |
● Cable length, shielded, max. |
200 m |
● Cable length unshielded, max. |
200 m |
Digital outputs |
Number of digital outputs |
2 |
short-circuit protection |
Yes; Electronic |
● Response threshold, typ. |
Response threshold (short-circuit): 5 to 12 A; response threshold (external short-circuit to ground): 5 to 12 A; response threshold (external short-circuit to P potential): 25 to 45 A |
Limitation of inductive shutdown voltage to |
L (-2x 47 V) |
Controlling a digital input |
No |
Switching capacity of the outputs |
● Lamp load, max. |
10 W |
Load resistance range |
● lower limit |
12 Ω |
● upper limit |
1 kΩ |
Output voltage |
● for signal "1", min. |
L (-2,0 V), current sourcing switch: L (-1,5 V), voltage drop on current sinking switch: max. 0.5 V |
Output current |
● for signal "1" rated value |
2 A |
● for signal "1" permissible range for 0 to 60 °C, min. |
20 mA |
● for signal "1" permissible range for 0 to 60 °C, max. |
2.4 A |
● for signal "0" residual current, max. |
0.5 mA |
Parallel switching of 2 outputs |
● for increased power |
No |
● for redundant control of a load |
No |
Switching frequency |
● with resistive load, max. |
30 Hz |
● with inductive load, max. |
0.1 Hz |
● on lamp load, max. |
10 Hz |
Aggregate current of outputs (per group) |
horizontal installation |
— up to 40 °C, max. |
10 A |
— up to 55 °C, max. |
7 A |
— up to 60 °C, max. |
6 A |
vertical installation |
— up to 40 °C, max. |
6 A |
Relay outputs |
Switching capacity of contacts |
— at ohmic load, up to 50 °C, max. |
10 A |
Cable length |
● Cable length, shielded, max. |
200 m |
● Cable length unshielded, max. |
200 m |
Interrupts/diagnostics/status information |
Diagnostic messages |
● Diagnostic functions |
Yes |
● Diagnostic information readable |
Yes |
● Diagnostics |
Yes |
● Wire break |
Yes |
● Short circuit |
Yes |
● Missing load voltage |
Yes |
Diagnostics indication LED |
● Rated load voltage PWR (green) |
Yes |
● Group error SF (red) |
Yes |
● Status indicator digital output (green) |
Yes |
Galvanic isolation |
Galvanic isolation digital outputs |
● between the channels |
No |
● between the channels and the backplane bus |
Yes |
● between the channels and the load voltage L |
No |
Isolation |
Isolation checked with |
500 V DC |
tested with |
● Channels against backplane bus and load voltage L |
500 V DC |
Standards, approvals, certificates |
Highest safety class achievable in safety mode |
● acc. to EN 954 |
4 |
● acc. to IEC 61508 |
Up to SIL 3 |
Dimensions |
Width |
30 mm |
Height |
81 mm |
Depth |
52 mm |
Weights |
Weight, approx. |
88 g |
last modified: |
25.09.2014 |