SIMATIC DP, 5 ELECTRON. MODULES FOR ET 200S, 4 DO SHIGH FEATURE 24V/2A DC, 15 MM WIDTH DIAGNOSIS SHORT CIRCUIT, SF-LED 5 PIECES PER PACKAGING UNIT |
|
Supply voltage |
Reverse voltage protection |
Yes; when using the same load voltage as on the power module |
Load voltage L |
Rated value (DC) |
24 V; From power module |
Reverse polarity protection |
Yes; polarity reversal can lead to the digital outputs being connected through |
Input current |
from load voltage L (without load), max. |
5 mA; Per channel |
from backplane bus 3.3 V DC, max. |
10 mA |
Power losses |
Power loss, typ. |
1.6 W |
Address area |
Address space per module |
with packing |
4 bit |
without packing |
1 byte |
Digital outputs |
Number of digital outputs |
4 |
Short-circuit protection |
Yes |
Response threshold, typ. |
5 to 10 A |
Limitation of inductive shutdown voltage to |
L -(37 to 41V) |
Controlling a digital input |
Yes |
Load resistance range |
lower limit |
12 Ω |
upper limit |
3400 Ω |
Output voltage |
for signal "1", min. |
L (-1.0 V) |
Output current |
for signal "1" rated value |
2 A |
for signal "1" permissible range for 0 to 60 °C, min. |
7 mA |
for signal "1" permissible range for 0 to 60 °C, max. |
2.4 A |
for signal "0" residual current, max. |
0.5 mA |
Output delay with resistive load |
"0" to "1", max. |
250 µs |
"1" to "0", max. |
400 µs |
Parallel switching of 2 outputs |
for increased power |
No |
for redundant control of a load |
Yes; per module |
Switching frequency |
with resistive load, max. |
100 Hz |
with inductive load, max. |
2 Hz |
on lamp load, max. |
10 Hz |
Aggregate current of outputs (per group) |
horizontal installation |
up to 60 °C, max. |
4 A |
vertical installation |
up to 40 °C, max. |
4 A; At 55 °C and 24 V DC |
Cable length |
Cable length, shielded, max. |
1000 m |
Cable length unshielded, max. |
600 m |
Isochronous mode |
Isochronous operation (application synchronized up to terminal) |
Yes |
Interrupts/diagnostics/status information |
Diagnostic messages |
Diagnostic functions |
Yes |
Short circuit |
Yes; Module-wise |
Diagnostics indication LED |
Group error SF (red) |
Yes; SF-LED (red) |
Status indicator digital output (green) |
Yes; Per channel |
Galvanic isolation |
Galvanic isolation digital outputs |
between the channels |
No |
between the channels and the backplane bus |
Yes |
Isolation |
Isolation checked with |
500 V DC |
Dimensions |
Width |
15 mm |
Height |
81 mm |
Depth |
52 mm |
Weights |
Weight, approx. |
40 g |
Status |
May 14, 2014 |