SIMATIC DP, ELECTRONIC SUBMODULE FOR ET 200ISP, 4 DO, DC 23,1V/20MA, "H"-SHUT DOWN |
Input current |
from load voltage L (without load), max. |
340 mA; with actuator supply |
from backplane bus 3.3 V DC, max. |
10 mA |
Power losses |
Power loss, typ. |
2.5 W |
Address area |
Address space per module |
● without packing |
2 byte |
Digital outputs |
Number of digital outputs |
4; additionally 1 intrinsically-safe input for H shutdown |
short-circuit protection |
Yes |
No-load voltage Uao (DC) |
23.1 V |
Internal resistor Ri |
275 Ω |
Trend key points E |
● Voltage Ue (DC) |
17.1 V |
● Current Ie |
20 mA |
Output current |
● for signal "1" rated value |
0.02 A |
Output delay with resistive load |
● "0" to "1", max. |
2 ms |
● "1" to "0", max. |
1.5 ms |
Parallel switching of 2 outputs |
● for increased power |
No; for Ex reasons not possible; nor for predecessor |
Switching frequency |
● with resistive load, max. |
100 Hz |
● with inductive load, max. |
2 Hz |
Cable length |
● Cable length, shielded, max. |
500 m |
● Cable length unshielded, max. |
500 m |
Interrupts/diagnostics/status information |
Status indicator |
Yes |
Alarms |
● Diagnostic alarm |
Yes; Parameterizable |
Diagnostic messages |
● Diagnostic functions |
Yes |
● Diagnostic information readable |
Yes |
● Wire break |
Yes; R > 10 kohms, I < 100 µA |
● Short circuit |
Yes; R< 800 ohms (one output), R< 40 ohms (outputs connected in parallel) |
Diagnostics indication LED |
● Group error SF (red) |
Yes |
● Status indicator digital output (green) |
Yes |
Parameter |
Diagnosis: wire break |
Yes |
Diagnosis: short circuit |
Yes |
Behavior on CPU/Master STOP, channel-wise |
Substitute a value/keep last value |
Ex(i) characteristics |
Max. values of output circuits (per channel) |
● Ta (permissible ambient temperature), max. |
70 °C |
Galvanic isolation |
Galvanic isolation digital outputs |
● between the channels |
No |
● between the channels and the backplane bus |
Yes |
● between the channels and the load voltage L |
Yes |
Standards, approvals, certificates |
Use in hazardous areas |
● Type of protection acc. to EN 50020 (CENELEC) |
II2 G (1) GD Ex ib[ia] IIC T4 and I M2 Ex ib[ia] I |
● Type of protection acc. to KEMA |
04 ATEX 1249 |
Dimensions |
Width |
30 mm |
Height |
129 mm |
Depth |
136.5 mm |
Weights |
Weight, approx. |
255 g |
last modified: |
25.09.2014 |